. This can be caused by incorrect credentials, blocked ports, or a corrupted WMI repository on the target machine. Immediate Troubleshooting Steps Verify Network Connectivity
If all else fails, enable OMI debug logging (set loglevel=DEBUG in omiserver.conf ) and check logs in /var/log/omi (Linux side) or C:\ProgramData\omi\log (Windows side) for exact failure reason. win32-operatingsystem result not found via omi
// Create the instance object MI_Instance* instance; My_Native_OperatingSystem_CreateInstance(&instance, context); win32-operatingsystem result not found via omi
The failure is rarely due to the class definition itself missing, but rather how OMI interacts with the underlying OS data sources. There are three primary causes for this behavior: win32-operatingsystem result not found via omi
omicli wql "SELECT * FROM Win32_OperatingSystem"
: Ensure the following ports are open between the collector/server and the Windows host: (RPC Endpoint Mapper) TCP/5985-5986 (WinRM HTTP/HTTPS) Check User Permissions : The user must be a member of the local Administrators' Group