Should we look into like soil-structure interaction or the best CDP parameters for historic masonry?
For a full time-history analysis with material non-linearity (e.g., steel yielding), Explicit is often preferred because seismic excitation lasts 10–60 seconds but requires resolving waves up to 10–20 Hz. For a linear-elastic response spectrum analysis, Standard is efficient. abaqus earthquake analysis